Thermally Stimulated Depolarization Current (TSDC) Testing
CMA Certified Lab (No. 261721340056)⏱ Within 5 working days

Thermally Stimulated Depolarization Current (TSDC) Testing

Apparatus:TSDC / CPS System

Technical Specifications & Test Capabilities

Parameter / MetricSpecification Range & AccuracyOperational Notes
Temperature Range-160°C to 450°CLinear heating rates from 0.5 to 10°C/min
Current Detection Range0.1 pA to 10 mA (Sub-pA resolution)Femtoampere-level electrometer amplifier
In-Situ Poling Voltage±100 V to ±1000 V (Expandable to ±5 kV)In-situ high-temperature electric field alignment
Analytical DeliverablesDepolarization current spectrum, Trap energy depth, Pyroelectric PiInitial rise and peak shape fitting

Specimen Geometry & Preparation Guide

Material FormRecommended DimensionsDimensional LimitsElectrode & Poling Notes
Bulk Ceramics & CrystalsDiameter ≤ 30 mm, thickness ≤ 5 mmDouble-sided silveredExternal or in-situ poling available
Polymer Films (PVDF, PTFE, Kapton)Thickness 5–20 µm, sputtered Au Ø3–5 mmFilm 2D size slightly larger than electrodeHigh gold layer thickness (> 50 nm) for uniform current

Testing Function

Thermally Stimulated Depolarization Current (TSDC / TSC) is an ultra-sensitive macroscopic probe of microscopic dipole relaxation, charge trapping, and defection energetics in dielectric, ferroelectric, and electret materials. By polarizing specimens at elevated temperatures, freezing dipoles at cryogenic levels, and measuring released picoampere depolarization currents during linear heating, this test reveals trap energy depths, relaxation time distributions, and true pyroelectric coefficients.

Testing Conditions

Primary Instruments: TSDC / CPS System
Standard Turnaround: Within 5 working days
Key Standards: ASTM D257 / IEC 62631 Standards for Dielectric Relaxation Characterization

Sample Requirements

Please review the detailed specimen dimensions, electrode requirements, and poling conditions in the table above. Custom dimensions and special sample geometry can be accommodated upon technical consultation.

Testing Standards

  • ASTM D257 / IEC 62631 Standards for Dielectric Relaxation Characterization

Test Results

Clients receive comprehensive test reports with raw exported ASCII/txt data files, high-resolution curve plots (temperature spectra, impedance plots, or hysteresis loops), and experimental condition parameters stamped by our CMA accredited testing center.