Ultra-High-Temperature Conductor Resistivity Testing (1600°C)
CMA Certified Lab (No. 261721340056)⏱ Within 5 working days

Ultra-High-Temperature Conductor Resistivity Testing (1600°C)

Apparatus:RMS-1650C

Technical Specifications & Test Capabilities

Parameter / MetricSpecification Range & AccuracyOperational Notes
Temperature RangeRoom Temperature to 1600°CInert / vacuum / reducing gas compatible furnace
Measurement TechniqueKelvin four-terminal double bridgeOvercomes micro-ohm contact resistance
Target MaterialsGraphite, C/C composites, platinum, tungsten, molten glassDedicated high-temperature clamping and crucible fixtures
Primary OutputsR-T, ρ-T, σ-T curves, heating/cooling hysteresisComplete thermal expansion corrected resistivity

Specimen Geometry & Preparation Guide

Material FormRecommended DimensionsDimensional LimitsElectrode & Poling Notes
Refractory Bar Specimen15 × 5 × 2 mmLength ≥ 10 mm, width ≥ 2 mmGraphite, carbon felt, metal alloys
Molten Glass / Slag SpecimenPre-weighed granular batch (2–5 g)Dedicated alumina/platinum crucible cellMeasures ionic conductivity across melting transitions

Testing Function

Refractory conductors, graphites, and carbon-carbon composites deployed in metallurgy, chemical engineering, and hypersonic aerospace must maintain predictable electrical transport under extreme heat up to 1600°C. Our RMS-1650C system utilizes a precision Kelvin four-terminal bridge to cancel high-temperature lead resistance, delivering reliable resistivity curves for solid refractories as well as ionic conductivity of molten glasses.

Testing Conditions

Primary Instruments: RMS-1650C
Standard Turnaround: Within 5 working days
Key Standards: ASTM C611 Standard Test Method for Electrical Resistivity of Manufactured Carbon and Graphite Articles

Sample Requirements

Please review the detailed specimen dimensions, electrode requirements, and poling conditions in the table above. Custom dimensions and special sample geometry can be accommodated upon technical consultation.

Testing Standards

  • ASTM C611 Standard Test Method for Electrical Resistivity of Manufactured Carbon and Graphite Articles

Test Results

Clients receive comprehensive test reports with raw exported ASCII/txt data files, high-resolution curve plots (temperature spectra, impedance plots, or hysteresis loops), and experimental condition parameters stamped by our CMA accredited testing center.

Dual-Funnel Validation

Turnkey Equipment for Your Own Laboratory

Prefer in-house characterization? Every test in our laboratory is performed using MatMeas turnkey instruments. Verify measurement quality with sample testing before capital procurement.

Request High-Precision Testing Solutions

Get expert guidance and customized instruments for your functional materials project.